About
HaSS of ECG monitoring Vitappio™
Consists of Vitappio™ Holter monitor, software and Vitappio™ health server, providing the ability to carry out long-term remote registration in real time and to analyze the electrocardiogram, physical and respiratory activity of the patient, with the doctor's ability to access the data from any device with Internet access.
Vitappio™ hardware and software system can be integrated into various medical and hospital information systems (MIS and HIS), or work independently, as a stand-alone solution for hospitals of any type.
Small sized Holter monitor with electrodes, capable to work remotely outside of a medical institution, without restrictions on the records number sessions per patient and an unlimited quantity of days, taking into account a battery replacement and changing of a set of electrodes every 24 hours.
Software (a doctor and a nurse workplace) and a server (virtual or local), allowing remote registration of the patient's diagnostic data, as well as analyzing the received data, easing the doctor's work with a massive amount of data.
Advantages
Description
Operation modes
The complex can work both in the presence of specialized specialists, and in their lack (or absence) in a medical and preventive institution.
Single center for functional diagnostics
Clinic with functional diagnosticians staff
- Patients with the Vitappio™ holter
- Doctor’s work station Vitappio™ health
Single center for functional diagnostics
Clinic with functional diagnosticians staff
- Patients with the Vitappio™ holter
- Doctor’s work station Vitappio™ health
Clinics
Clinics without specialists in some healthcare facilities
- Nurse’s work place Vitappio™ health
- Doctor’s work station Vitappio™ health
Distant interpretation of diagnostic indicators with the involvement of medical experts and / or leading cardiology centers in the country
Single center for functional diagnostics
Clinic with functional diagnosticians staff
- Patients with the Vitappio™ holter
- Doctor’s work station Vitappio™ health
Clinics
Clinics without specialists in some healthcare facilities
- Nurse’s work place Vitappio™ health
- Doctor’s work station Vitappio™ health
Technical Specifications
data transfer to the system
data from previous sessions
measuring range
movement ± 2g,
100 Hz in 3 axes
of electrodes ungluing
At a request of a customer directions of use are provided to the employees of the healthcare facilities during the delivery of the system both: at a visit to the customer and in a remote way.
All supplied equipment, with the exception of electrodes, has got a 12 - month warranty from the date of delivery.
Post-warranty service is possible on commercial basis.
Vitappio™ holter Modifications
Cardisens – 1
- Registration of 3 leads (I, II, III);
- The main purpose of use is the search of cardiac rhythm disturbances and monitoring the patient's condition;
- The most compact model. It does not have any cable;
- It is kept on 4 electrodes, what allows to increase the duration of ECG monitoring;
- Patient can change the electrodes by himself;
- Recommended for Arrhythmology departments, together with departments of neurology, surgery, etc., where the main purpose of the analysis is to exclude life-threatening arrhythmias.
Cardisens – 2
- Registrations of 7 leads (I, II, III, aVL, aVR, aVF, V);
- Chest leads are added, that allow to use the device as well to assess exercise tolerance and monitor patients with coronary artery disease (CHD);
- Recommended for departments of cardiology, therapy, etc., working with patients with CHD.
Vitappio™ health versions
Basic version | Expanded version* | |
---|---|---|
Automatic recognition of complexes | ||
Overview (making plots and tables) | ||
ST analysis | ||
TT analysis | ||
Classification defining | ||
Templates | ||
Reports | ||
QT analysis | — not available | |
BCP and BCP trends | — not available |
* recommended for arrhythmology departments
Cooperation
Fill out the application and our manager will contact you in the short term.
Please, fill in all the fields in the form — the information is necessary for our internal processes and facilitates further work with you. No one except us will use this information!